
[Jun-2026] Use Real HQT-4160 Dumps - 100% Free HQT-4160 Exam Dumps
HQT-4160 PDF Dumps Exam Questions – Valid HQT-4160 Dumps
NEW QUESTION # 32
How many Accelerator Compression Modules are installed in a VSP 5600?
- A. three per controller
- B. two per system
- C. two per controller
- D. two per CBX
Answer: C
Explanation:
Each controller in the VSP 5600 system is equipped with two Compression Accelerator Modules.
NEW QUESTION # 33
You need to install an iSCSI channel board feature on a VSP 5500 system. Which two steps are required? (Choose two.)
- A. Physically install the pair of channel boards in any available slot.
- B. Use the Maintenance Utility (Sub Panel) of the VSP GUI to assign ports to the added boards.
- C. Use the Maintenance Utility to add the boards to the system configuration.
- D. Physically install the pair of channel boards in the appropriate slots.
Answer: C,D
Explanation:
Physically install the pair of channel boards in the appropriate slots.
Channel boards must be installed in specific, designated slots to ensure proper system recognition and redundancy.
Use the Maintenance Utility to add the boards to the system configuration.
After installation, the Maintenance Utility is used to logically add and configure the new channel boards within the system.
NEW QUESTION # 34
You need to add another SBX with 4 drive boxes (DBS2) and 16 drives to a VSP 5100. What is the correct procedure?
- A. Insert the drives in the DBs. Mount the DBs in the rack and attach the cables. Install the drives with the Maintenance Utility.
- B. Mount the empty DBs in the rack. Insert the drives in the DBs and install them with the Maintenance Utility.
- C. Insert the drives in the DBs. Mount the DBs in the rack and install them with the Maintenance Utility.
- D. Mount the empty DBs in the rack and attach the cables. Install the DBs with the Maintenance Utility. Insert the drives in the DBs and install them with the Maintenance Utility.
Answer: B
Explanation:
The correct procedure is to first mount the empty drive boxes (DBs) in the rack, then insert the drives into the DBs, and finally use the Maintenance Utility to install and configure the new hardware. This ensures proper detection and initialization by the system.
NEW QUESTION # 35
Which three Channel Board (CHB) protocols are supported on a VSP 5000 system? (Choose three.)
- A. FC
- B. iSCSI
- C. SCSI
- D. Wide SCSI
- E. FICON
Answer: A,B,E
Explanation:
iSCSI
The VSP 5000 supports iSCSI Channel Boards, enabling block storage over IP networks.
FICON
FICON Channel Boards are supported for mainframe connectivity.
FC
Fibre Channel (FC) Channel Boards are supported for high-performance SAN connectivity.
NEW QUESTION # 36
Which tool is used for part replacement in a VSP 5000 system?
- A. Hi-Track
- B. Maintenance Utility
- C. Storage Navigator
- D. Web Console
Answer: B
Explanation:
The Maintenance Utility is the designated tool for performing part replacement operations in a VSP 5000 system. It provides the necessary procedures to safely block, replace, and unblock hardware components.
NEW QUESTION # 37
Which three statements are correct regarding the cache configuration of VSP 5000 systems with two controller boxes (CBX)? (Choose three.)
- A. Each controller pair (CTL1-CTL1, CTL2-CTL2) must have the same cache capacity.
- B. CMG0 must be used as default and CMG1 is optional.
- C. The cache only support 128 GB DIMMs.
- D. All the DIMMs must be of the same type.
- E. CMG0 or CMG1 can be used as default cache.
Answer: A,B,D
Explanation:
All the DIMMs must be of the same type.
Cache DIMMs are installed in groups (CMGs) of four, and all DIMMs within each group must be identical in capacity and speed to ensure correct interleave and performance.
CMG0 must be used as default and CMG1 is optional.
On each controller, you populate the CMG0 slots first - this becomes the active (default) cache and only after CMG0 is filled can you populate CMG1 for additional capacity.
Each controller pair (CTL1-CTL1, CTL2-CTL2) must have the same cache capacity.
Controllers operate in mirrored pairs and require symmetric cache configurations so that each side of the pair holds identical cache capacity for failover and data integrity.
NEW QUESTION # 38
Which document is essential to review before starting the pre-installation process for a VSP 5000 storage system?
- A. The latest software compatibility list
- B. The annual maintenance contract
- C. The customer service plan
- D. The installation site requirements
Answer: D
Explanation:
Before beginning the pre-installation process for a Hitachi VSP 5000, it is crucial to review the installation site requirements. This ensures that the physical environment is suitable for the system and meets operational standards. Key factors include:
Rack space and floor loading for the storage system
Power requirements (voltage, redundancy, and distribution)
Cooling and airflow specifications
Network connectivity requirements
Environmental considerations such as humidity, temperature, and dust control Reviewing this document helps avoid delays, prevent equipment damage, and ensures a smooth installation.
NEW QUESTION # 39
The creation of Parity Groups is essential for which aspect of VSP 5000 storage systems?
- A. Data protection and performance
- B. Power consumption reduction
- C. User management
- D. Network configuration
Answer: A
Explanation:
In the Hitachi VSP 5000 storage system, Parity Groups are used to implement RAID configurations, which are fundamental for:
Data protection - Parity information allows the system to rebuild data in case of a drive failure, preventing data loss.
Performance optimization - Spreading data across multiple drives with parity improves read/write throughput and I/O efficiency.
Parity Groups are essentially the building blocks of storage pools, and they determine the balance between capacity, redundancy, and performance.
NEW QUESTION # 40
Which management tool is used to create a Parity Group in a VSP 5000 system?
- A. Hitachi Command suite
- B. Web Console
- C. Maintenance Utility
- D. Storage Navigator 2
Answer: D
Explanation:
Storage Navigator 2 is the primary management tool used for configuring and managing storage on VSP 5000 systems, including the creation of Parity Groups.
NEW QUESTION # 41
How is the internal SVP IP address set up on a VSP 5000 system?
- A. It is generated by the SSVP.
- B. It must be set up by the customer's network administrator.
- C. Using the "Set IP Address" on the SVP GUI.
- D. The Hitachi Distribution Centers pre-configure the same IP address on all new machines.
Answer: A
Explanation:
The internal SVP IP address on a VSP 5000 system is automatically generated by the SSVP (Service Support Processor) during system initialization and is not manually configured.
NEW QUESTION # 42
In a VSP 5100 a drive in a RAID5 Parity Group has failed and has been blocked by the microcode. As a result, which process gets automatically started?
- A. Dynamic Sparing
- B. Copy Back
- C. Sparing Copy
- D. Correction Copy
Answer: D
Explanation:
When a drive in a RAID5 Parity Group fails and is blocked by the microcode in a VSP 5100, the Correction Copy process is automatically started to rebuild the data onto a spare drive.
NEW QUESTION # 43
Which three VSP storage systems are monitored by the Hitachi Remote Ops SVP Agent (Choose three.)
- A. VSP G1500
- B. VSP 5200H
- C. VSP E1090
- D. VSP F900
- E. VSP G800
Answer: A,D,E
Explanation:
These VSP storage systems are monitored by the Hitachi Remote Ops SVP Agent, which provides remote monitoring and support for enterprise-class Hitachi storage platforms.
NEW QUESTION # 44
How do you validate the network settings configuration on a newly installed VSP 5000 storage system?
- A. Using an external network configuration audit tool
- B. By disconnecting and reconnecting the network cables
- C. By performing a system reboot
- D. Through the management console's network test function
Answer: D
Explanation:
The Hitachi VSP 5000 storage system provides a built-in management interface that allows administrators to verify configuration settings after installation.
Using the management console network test tools, administrators can:
Validate IP configuration
Check network connectivity
Verify gateway and DNS settings
Test communication with management hosts or monitoring systems
These built-in diagnostic functions help ensure that the network configuration is correct and operational before the system goes into production.
NEW QUESTION # 45
Which two manuals should be used when troubleshooting on a VSP 5000 system? (Choose two.)
- A. Troubleshooting manual
- B. Installation manual
- C. Maintenance manual
- D. Service Guide
Answer: A,C
Explanation:
Troubleshooting manual
This manual provides detailed procedures and steps for diagnosing and resolving issues on the VSP 5000 system.
Maintenance manual
The Maintenance manual contains instructions and information needed for maintenance activities, including troubleshooting steps and part replacement guidance.
NEW QUESTION # 46
What is a critical step in the pre-installation checklist for ensuring the physical security of the VSP
5000 system?
- A. Configuring firewall settings
- B. Setting BIOS passwords
- C. Installing surveillance cameras in the data center
- D. Securing the racks to the floor
Answer: D
Explanation:
The Hitachi VSP 5000 is a large enterprise storage system typically installed in data center racks.
A key pre-installation physical security and safety requirement is ensuring that racks are properly anchored or secured to the floor.
This step is critical because:
The storage system is heavy and tall, creating a tip-over risk.
Anchored racks improve stability during maintenance (when components are extended).
It protects equipment from accidental movement or vibration.
Many data center safety standards require rack anchoring before installation.
NEW QUESTION # 47
What are the key benefits of correctly performing a "New Installation" procedure for VSP 5000 storage systems? (Choose Three)
- A. Enhanced system security
- B. Extended hardware lifespan
- C. Optimal system performance
- D. Increased storage capacity
- E. Reduced risk of installation-related issues
Answer: A,C,E
Explanation:
Performing a proper new installation procedure for the Hitachi VSP 5000 ensures that the system is set up correctly and ready for reliable operation. Key benefits include:
Optimal system performance (B)
Correct configuration of storage controllers, network connections, and RAID groups ensures efficient I/O handling and system throughput.
Enhanced system security (C)
Properly configuring access controls, user permissions, and network settings helps protect data and prevent unauthorized access.
Reduced risk of installation-related issues (D)
Following the recommended steps minimizes errors such as connectivity problems, misconfigured storage, or hardware misalignment, which could lead to downtime.
NEW QUESTION # 48
......
Ultimate HQT-4160 Guide to Prepare Free Latest Hitachi Practice Tests Dumps: https://pass4sure.verifieddumps.com/HQT-4160-valid-exam-braindumps.html
